Additions

1) Removed the Validation messages of charge and repair codes as they were being entered on the main screen and transferred this validation to the Validate data option under the tools menu.

2) When validating data a surplus message appeared after any errors were Found. This has now been removed.

3) Added support for downloading the Metrel SigmaPat MI3310

4) Added support for downloading the Seaward PAT1000

5) Added support for downloading the Seaward PAT2000

6) Moved support for downloading the Seaward Primtest 300, Seaward Primtest 350, Seaward 1000S, Seaward 1000x, Seaward IT1000 and Metrohm MPAT60 from the separate download utility into the main SimplyPats program.

7) Added the ability to store the Notes or Comment lines from all of the PAT testers into a nominated field within SimplyPats. You can now select to store the notes field from the PAT into Appliance Serial Number, Retest Period, Notes, User/Engineer, Fuse Rating, Site, Location, Appliance Description, or Charge and Repair codes.

8) Rewritten the Download PAT screen allowing you to easily swap between downloading different PAT testers.

9) Added functionality on the download screen to allow you to specifically set a com port for those testers which try and detect the com port and baud rate automatically. This may useful when downloading to PCs which have a large number of odd com ports.

10) Added a refresh button on the download screen to re detect any com ports. This is useful where you may have forgotten to plug in your USB serial converter after SimplyPats is already running.

11) Added a button to automatically start the Windows Device Manager screen. This may help when diagnosing which com ports are installed on your PC and to check that the drivers have been installed for any USB to serial converters.

12) Added a new function that automatically backs up the raw data download file of your PAT tester. These files are date ad time stamped and kept safe in a new rawdata folder within SimplyPats, ensuring you can always recover the original data as it was first downloaded from your PAT tester.

13) Added detection of the RCD tests produced by the Metrel BetaPat MI3304 and OmegaPat Plus MI3305 these are now stored within SimplyPats.

14) Detection of the RCD tests on the New Zealand and Australian versions of the Metrel BetaPat MI3304 and OmegaPat Plus MI3305 includes recording the phase results in the notes field in SimplyPats.

15) Added specific help for downloading each PAT tester on the settings screen for each PAT tester.

16) Rewritten the Upload Screens for the Megger PAT4, Seaward Europa Plus and Supernova Plus and Transmille PAT Testers. The upload screen now has the same look and feel as the new download PAT Settings Screen.

17) Added specific help for uploading each PAT tester on the settings screen for each PAT tester.

18) Added a new option on the Bulk Replace screen (where you have selected a range of tests) to remove any leading zeroes from your Appliance Id's. This may be useful if you have a barcode scanner set to automatically input leading zeroes, or you have data from a PAT test machine that automatically inputs leading zeroes.

19) Added options to Print the information on the Customer Details Screen and Invoicee Details Screen.

20) Added support for downloading the Metrel DeltaPat MI3309

21) Added a new keyboard shortcut (CTRL+F5) from the Main SimplyPats screen to bring up the Manual Entry Screen.

22) Added Leakage test results to the V2 Passes, Fails and Passes And Fails Report.

23) When selecting a specific site and location to be printed from the Print Screen a surplus message appeared telling you to select a site or location before you had a chance to do so. This message has been removed.

24) Added a tick box on the Invoice Screen and Reprint Invoice screen to allow printing of a receipt for an invoice.

25) Added Fail Reason and Notes fields to the Manual Entry Screen.

26) When selecting records, if you have grouping on e.g. all appliances grouped by location. When right clicking on an appliance in a group on the main grid and choosing Select All records from the drop down menu, you will be asked if you just want to highlight just the records of the current group rather then all of your records.

27) Add a function to the Invoicing within SimplyPats so that you can create and invoice based on highlighted records only.

28) Add support for Megger PAT420 Firmware Revision. Importing CSV files from the Megger PAT420 stopped working after Megger revised their firmware to 2.10 from 2.00. SimplyPats can now deal with data from either firmware from this PAT Tester.

29) Amended the RCD Manual Entry screen to allow the setting of the test current. This will now allow Australian and New Zealand users to enter Type I rcd's e.g. less than 40 mS at 10 mA.

30) Added a New printed RCD Report that shows the test results at 0 and 180 degrees phase for newer PAT testers (Metrel SigmaPat Plus, BetaPat and OmegaPat Plus) that download that information. This is especially for the New Zealand and Australian regulations.

31) Amended the Hide Skips option on the Systems Settings screen so that only the test results with values are shown in the Test Results area of SimplyPats (Top Right Window of Main Screen) No skipped tests, or blank lines are now shown.

32) Amended the inspHire rental software CSV import routine to improve handling of data exported from inspHire containing missing test dates and quotation marks within appliance descriptions.

33) Added support for downloading the Kewtech KT77 Pat Tester.

34) Removed surplus message appearing if Spell Check was cancelled mid way through Spell Checking.

35) Added a new keyboard shortcut (CTRL+F6) from the Main SimplyPats screen to Edit a Manual Entry Test.

36) Added a button to automatically create a PDF and Email to your customer from the Non Appliance Print Preview Screens. E.g. When Creating an Invoice.

37) Removed the Add Visual Tests options from the Records menu as these functions have been superseded by the Manual Entry Screen.

38) Added a menu option on the Records menu to edit a Manual Entry test.

39) Rewritten the Email SimplyPats data file button on the Main Screen so that it is easier to send the complete data file to a recipient. You are now only prompted to Email Selected records to a recipient if you have 2 or more records highlighted.

Bugs

1) When using the System Settings screen on the Manual Version of SimplyPats, if you had no com ports available on your PC, a message appeared saying this and stopped you making any changes to the settings. This has now been fixed for the manual version.

2) When downloading the OmegaPat Plus MI3305 where flash tests have been done and recorded a value of <0.2 SimplyPats stopped with an error. This has now been fixed.

3) When downloading the Megger PAT4 if you had set your own group code (test code) and chosen not to undertake a Visual Test, SimplyPats did not record the Visual Test as being skipped but set it as a failed visual test.

4) When downloading the Transmille 6080 or Transmille 6080 Plus, the earth Continuity output was being incorrectly read, stating a 25A output when 100mA test was done. This has now been fixed.

5) Amended the Overdue Appliance Screen and report so that failed items are not included.

6) Amended the 1 applpiance per page report and detailed passes and fails report (both old and new versions) to correctly show clamp test results.

7) If you had replaced Location or Site abbreviations and then imediately gone to the List Sites screen, the unique Sites displayed had not been updated and so saving the sites data as a separate file did not work. This has now been fixed.

8) Version 2 Reports Hide Cut Marks Around Logo tick box on the Margins and Colours tab of the Print Settings Screen did not work. This has now been fixed. The same Version 2 Reports Hide Cut Marks Around Logo tick box on the Logo and Fonts tab has beeen removed.

9) When hiding Cut Marks Around Logo option was ticked it did not remove the cut marks around the Version 2 Certificate of PAT testing. This has now been fixed.

10) Fixed a bug when double clicking a row header on a Manual Entry Test not selecting the correct testing information.

11) On the Manual Entry screen, when adding a new user to your last test, on restarting the Manual Entry screen that user wasn't avaialble.

12) On the review Customers screen, when finding Retests due Between 2 dates the results were showing the first retest due in that customer file, not just those customers whose retests dates fell in that period.

13) When printing a list of Sites using the from the List Sites screen, the report referred to locations not sites.

14) Everywhere in SimplyPats where you could load an image, e.g. company logo, signature image for reports, or add photo to an appliance, you were given the option of looking for gif type images. However if you selected files of type gif, no gif images would be listed even though they were present. This has now been fixed.


Revision History
Version: 6.0.4 04th May 2011
  • 1) Added support for loading CSV data produced by the Megger PAT420 Pat Tester. Note, this hasnt been checked with the data produced by the PAT410 or PAT450 as yet.

    2) Added the ability to set the height of your signature image which is shown on the new style reports. The signature image shown on the Certificates is unchanged.

    3) Added another field in the print Setup screen to allow you to print a second line of free text at the top of your invoice. This could be used to print a promotional offer for example.

    4) Increased the maximum length of a Site or Location abbreviation from 5 to 7 characters.

    5) Added the ability to change the fore colour on the version 2 banners as well as the back colour. You can also set the colours of the other shaded areas on the version 2 report.

    6) Added a Message Box confirming a successfull backup after using the Backup Your Data feature from the Settings Menu.

    7) Added a new option on the Edit Prnt Sequence screen to allow the single PDF to be created in the same folder as your current data file.

    8) Amended the Edit Print Sequence screen so that you can set the Number of Print copies to zero and also select to not print a PDF. When you print your sequence this report will be excluded.

    9) Amended the length of the Email text box on the Customer Details and Invoicee Details screens from 35 to 50 characters. Also removed the validation of the email field as some users found this annoying.

    10) Added a Maximum Insulation Value box on the System Settings screen for manually entered tests. If the insulation value is greater than this max Value, then a greater than sign will appear on the test results on the mian screen and when printed.

    11) Added a tick box on the Print Settings screen to hide or show the 'crop marks' around the company logo on the version 2 reports.

    Bugs

    1) When printing a folder cover where your customer had no contact title entered (e.g. Mr, Mrs Miss etc) No contact name was shown on the folder cover. Now just Forename and Surname are shown.

    2) If non SimplyPats data file with the extension .pat was copied in your data folder, (or a totally unreadable SimplyPats file) the Customer Quick Select screen crashed as it tried to show the list. You are now asked to remove the offending file from the data folder.

    3) Amended spelling mistake of Simplyfied to Simplified in the Simplified Passes and Fails report. Also fixed an error in the same report where depending on the size of appliances in the first location, no appliances were printed on the first page of the report.

    4) When saving a PDF of a Pat Test Report, if your customer name contained a colon (:) then a runtime error 20477 Invalid File Name appeared. This error is now fixed, the colon is now being removed from the PDF Filename.

    5) When Printing the New V2 Microwave Report where there were than 1 page of Microwaves, SimplyPats raised an error 2014 and stopped. This bug has now been fixed.

    6) When Printing the New V2 Passes and Fails Pat Testing Report the appliances in a single location were not always kept together under that location, instead the same location was repeated. This problem has now been fixed.

    7) Fixed the issue of Clamp tests not being shown on reports. As many of the default reports do not have space for Clamp Data, you may need to contact us for custom reports to display the Clamp results.

    8) If you had ticked the Use Pat File Name on Export Save option on the System Settings screen, the create a single merged PDF of all your PAT reports failed. This has now been fixed.

    9) Fixed a typo on the email generated when creating a single PDF of all your pat testing reports. Changed Your Sincerely to Yours Sincereley.

    10) The menu option that appeared when you right click in the test results area to Edit A Manual entry test had dissapeared. This menu option has been reinstated.

    11) On the create Print Sequence screen, if the same report was entered more than once, an error was generated when printing the sequence. SimplyPats now checks that each report is only listed once.

    12) Clicking on the Clear Button of the Test Price field on either the Bulk replace or Bulk Replace Selection screens caused SimplyPats to stop working. This has now been fixed on both screens.

Version: 6.0.3 16th February 2011
  • Additions

    1) Added a complete suite of 12 New style Pat Testing Reports including user definable coloured headings.

    2) Added an option in the Edit Print Sequence Screen to automatically create A Single PDF containing all your selected PAT Testing Reports. This can also automatically attached to an email to your customer.

    3) Added a new screen to show all the overdue appliances in the current file and by how many days they are overdue. An option allows you to show appliances overdue by x number of days or by supplying a negative number, those appliances due for test in x days.

    4) Added a New Report to allow you to print Portable Appliance Testing Guidance Notes to your customer or end user. You can edit the text of the report using Microsoft Word (tm) You may use it to contain notes on recommended re test frequencies, risk assessment or contractual terms for example.

    5) Added a new feature in the Print Setup screen to add a watermark image to your PAT Testing Reports. E.g. Example Report.

    6) Added an NA (Not Applicable) option to the fuse rating selection on the Manual Entry Screen.

    7) Added a new option in the Print Settings screen to allow the One Appliance Per Page and Current Appliance reports to be printed in Red ink if they are a failed test.

    8) Calculated the Number of Visual Only tests performed in your current file and displayed the total on the Summary of Tests Screen. Also updated this screen to include how many RCD and Microwave Failed tests were found in the current file.

    9) Increased the maximum number of customer files that can be listed by the Review Customers, Quick Select customers and Retest Calendar screens from 3000 to 5000.

    10) Added an Ignore button on the Customer Quick Select screen and Review Customers screen to create a list of customers to be hidden on those screens. These ignored customers can also be shown / hidden on the Re tests Calendar screen. Ignored customers can be taken off the ignore list by selecting them and clicking the ignore button a second time. The purpose of this is remove customers or their data without actually deleting the SimplyPats data file.

    11) Amended the Metrel GammaPat MI 3311 download routine to cater for later revisions of the Metrel GammaPat Firmware. Sometime after Firmware Version 1.27 Metrel have added the ability for the Gamma Pat to enter an Appliance description in addition to the Appliance Id. SimplyPats will now download and make use of this Appliance Description if it is present.

    12) Amended the Megger PAT4 Download to put the contents of the Serial Number Field in the PAT4 into the Serial Number Field of SimplyPats. This will only happen when you choose not to use the Serial Number field on the PAT4 for entering Charge and Repair codes.

    13) Amended the Megger PAT4 download to correctly put the Fuse Rating from the PAT into the Fuse rating field in SimplyPats.

    14) Increased the Appliance Serial Number field from 20 characters to 25 characters.

    15) Added a third option on the print Labels screen so that the Test Date and Retest Date are NOT printed when you print PAT Testing Labels. This option may be useful for those users who wish to write in the test date and retest date whilst on site testing rather than having the dates printed in advance.

    16) Re-Ordered the list of Import Raw Data file options in the File Open dialogue so that the more popular Raw data files are at the top of the list.

    17) On Printing Pat Testing Labels, a new tick box allows you not to print any Appliance Id's. This allows you to print Labels with just your company name and engineer should you want to complete the rest by hand.

    18) Added the Email Address to the output of the create Mail Merge file from the Customer Quick Select Screen.

    19) Amended the maximum size that you can set your company logo height to, from 30mm to 40mm.

    20) Added the ability to bulk change the Test Time of an appliance under the Bulk Replace Selection screen.

    Bugs

    1) Amended Version 6 freely available custom certificate of PAT Testing by removing the dots from the signature line.

    2) On the Summary Of Repairs report if there were no repairs the Customer Name field at the top of the report would contain a weird date e.g. 30-Dec-1899. This has now been fixed to show the Customer Name even when there are no repairs. The report also states No Repairs Required.

    3) When you clicked on the Today button on the Re tests Calendar screen, Tomorrow was highlighted in error. The today button now highlights today.

    4) Trying to Bulk Change the Fuse Rating (on its own) on either a selection of tests or all tests stated that there was nothing to do. This has now been fixed.

    5) Trying to Bulk Change the Class of an Appliance (on its own) on either a selection of tests or all tests stated that there was nothing to do. This has now been fixed.

    6) On Import and Update, if the file that was being imported to update your master Pat testing file contained duplicate appliance id's (perhaps where an appliance has been tested and re tested.) then some blank tests were created in error. The import and update screen now checks that the file you are importing doesn't contain any blank or duplicate appliance id's, prompting you to fix them first, before going ahead with the import.

    7) On some the Martindale MicroPat Plus Testers it is possible to set the earth Continuity Limit to 1 Ohm. If this was done SimplyPats would not pick up the Earth continuity Results. (SimplyPats was not expecting such a high value for an Earth continuity Limit, as the Limit is usually set in the region of 0.2 Ohms.) However this has now been fixed. We would suggest that care should be taken to ensure the correct limits as recommended by the IET Code Of Practice are set on the PAT tester.

    8) On some users PC's where they had a custom colour scheme, the main grid group by box may have been set to an odd colour. The group by box is now forced to have a white background colour.

    9) On the Original Certificate of PAT testing, if you had chosen to print just the Month and Year for the retest date, if the month was a long month (number of characters not days) e.g. October, then the Restest Date was being wrapped onto a new line. If you also had an electronic signature loaded the wrapped date was only partially displayed.

    10) A check has been put in to ensure that the settings file for the main screen is not corrupt. This settings file stores the users preference as to the position and size of the main screen when SimplyPats starts.

    11) If you were using Microsoft Outlook Express (tm) as your email client. The button to automatically create a PDF and Email it on the Print Results screen did not attach the PDF correctly. This has now been fixed.

    12) The interpretation of Flash Test results on the Martindale MicroPat Plus Pat tester was incorrect, always failing the appliance with a very high reading 300 mA plus. This bug has now been fixed.

    13) If you had set a folder when exporting PDF's in an automatic Print Sequence that no longer exists, e.g. it has been deleted or was a missing removable drive, and error was created. This error is now trapped and a message given to change the path or replace the folder or drive.

    14) No automatic backup of the download file was made after downloading the Megger PAT4 when using the Auto Create Backup On Download feature on the System Settings Screen. This has now been fixed.

    15) On the SimplyPats Tests By Engineer Utility Version 2.0, the data path was permanently set to C:\Program files\SimplyPats 6\Data This has now been fixed so that it picks up the same data path as set by your main SimplyPats program.

Version: 6.0.2 15th September 2010
  • Additions

    1) If you have Office 2010 installed and you try and create a word document using SimplyPats, if you try and use the Example Body document which is in Word 97 format, an error was produced. This is caused by the Word Trust Center blocking of older Word Format documents. An error trap has now been put in explaining the error. You can solve the problem by relaxing the Word Trust Center settings for older Microsoft Word files, or by creating your own body document in the same version of Microsoft Office that you are using.

    2) Added an option on the Quick Select Customer screen to create a Mail Merge Data file. If you have a Word Processing program such as Microsoft Word (tm) you can use the file created from SimplyPats to mail merge a document to your customers.

    3) On the import and update data screen, if you chose to update the test results, the testcode used by your PAT Tester wasn't being copied in. (where applicable as not all PAT testers reveal any testcodes). The test code is now copied over.

    4) Increased the number of characters description available in the Maintain Extra Charges screen so that longer descriptions can be enetered for invoicing.

    5) Added suport for downloading the Metrel GammaPat MI3311

    6) Added an option to show a graph of the changes in Insulation Resistance, Continuity and Leakage test results over time. This may be useful in showing the possible degradation of insulation of an appliance. This option will only work where you have used unique appliance id's.

    7) Added an Not Appicable option (NA) under the fuses drop down. This option may be useful where you are testing appliances without a domestic 13amp plug. The NA option has also been added to the drop down controls on Bulk Selection screens as well.

    8) Added a new tick box option in the Print Setup screen (Passes and Fails TAB) to allow the showing of exact test results for Leakage, Sub Leakage, Touch Leakage, Flash and Clamp tests. Previously if a test result was less than 0.1 then SimplyPats showed and printed <0.1 with the less than sign. You can now override this to show the exact value e.g. 0.02

    9) Added a new option in the settings for the Megger PAT4/DV3 or PAT4/DV to allow the use of Room Id's in the Megger PAT4 for locations in SimplyPats.

    10) On the Manual Entry screen, if you enter a test time of 00:00 you will be prompted if you want all the subsequent tests you add to have a time of 00:00 set.

    11) Amended the maximum number of sites and locations in a single file from 1000 to 2000.

    Bugs

    1) On Selecting the Kewtech KT74 or Kewtech KT75 from the System Settings screen, the com port selection was not always remembered. This is now fixed. Also when downloading the Kewtech KT74 or Kewtech KT75 the download screen showed an animation but no confirmation of the amount of data being read.

    2) If you had a custom report designed for the Summary Of Repairs screen and this was included in your automatic print sequence, the custom report was not printed, only the default one. This is now fixed.

    3) Amended the internet check for when a newer version of SimplyPats is available so that it doesnt remind everyone one the first day of a new month but rather 90 days after what ever day SimplyPats last checked for an update.

    4) Put additional checks in the program to check whether your company logo image or signature file image are available. If these images were stored on a Server and the folder selected was what is known as a UNC path e.g. \\my server\shared docs\ as opposed to a logical drive z:\shared docs SimplyPats recorded an error. As a tip, if you install SimplyPats on a laptop and want to use it away from your office, copy any company logo image or signature image to the laptop's hard drive.

    5) After creating new Invoices the invoice number was being correctly incremented however not being saved in the program settings. When restarting SimplyPats the invoice number reverted to the original number. This has now been fixed.

    6) The File Open button on the Retests Calendar, Customer Extra Information screen, didnt work. This has now been fixed.

Version: 6.0.1
  • Additions

    1) Amended the Licence screen in SimplyPats so that the Licence button takes you to the SimplyPats 6 Licence page with the 34 character Licence Number pre filled in the web page.

    2) Added 72 months retest period to the bulk replace screen. This retest period had already been added to the bulk replace of a selection of tests screen.

    3) Added a section of help in the Downloading Your Pat help page for the Robin 5500. There is now separate help for the Robin 5000 and the Robin 5500

    4) Added to the Summary of tests screen an item showing the average number of minutes each test has taken in the current file. This maybe useful if you are employing an engineer to carry out tests for you and want to ensure they are not rushing the visual and plug top checks.

    5) Added the ability to show a unique certificate number (with a prefix) on the certificates. This is so they can be uniquely numbered and traceable like an invoice.

    6) Redesigned the Print Setup screen to group the various options into TABs. This should make it easier to find various options relating to the way things are printed.

    7) Added the ability to add a prefix to the Appliance Ids. This can be done by highlighting a range of tests and then using the Bulk Replace Selection screen from the Tools Menu.

    8) Added Find Next and Find Previous buttons on the Edit Manual Entry screen. This should speed up the process of editing a whole range of manual entered tests, e.g. when re testing a customer or your own site.

    9) Re organised the Manual Entry screen making it more landscape, this is to assist users who are using Netbooks where the maximum resolution is 1024 by 700 and the bottom of the Manual Entry screen could not be seen.

    10) Added support for Automatic Emailing from SimplyPats with Windows Live Mail and Mozilla Thunderbird.

    11) Amended the Tests By Engineer utility to work with Windows Version 7 and SimplyPats Version 6. The free Tests by Engineer will print a report of total number of tests by engineer for a given period. You can now also print a report of total number of tests done each month in a given period.

    12) Added a New Screen to Print PAT Testing labels on to existing label stock. This feature currently works with blank PAT Labels from AOK Lables and also those used with the Label Station Pro printer. This feature also allows you to create and print Appliance Id labels prior to testing and then create a SimplyPats data file. This latter feature maybe useful for those using the Manual Entry screen to enter data.

    13) Rewritten the Help pages on downloading your Kewtech KT74 or Kewtech 75 to include the screen shots of the download process.

    14) Added a new option to allow the importing of appliance data from the inspHire Specialist Hire and Rental Management Software.

    15) Added 2 new options in the Manual entry screen for calculating the next appliance id. These are specific to calculating the next Appliance Id where alpha numeric appliance id's are being used. E.g AP001, AP002 etc. SimplyPats now examines any alpha numeric appliance ids to try and calculate and format the next number.

    16) For a Manually Entered appliance, you can now double click the Appliance in the Main SimplyPats screen to edit that appliance, rather than using the right mouse click menus. Note, it can take a second or two for the Manual Entry screen to be displayed.

    17) Amended the maximum length of the Email field in Your Settings screen from 40 to 50 characters.

    18) Rewritten how your preferences for printing and other program settings are saved in order to speed up the program on exit.

    19) Added a new option on the menu that appears when you right mouse click the customer address on the Main Screen to copy the customer details to the clip board. There is also a button that copies the customer address to the clip board on the Customer Details screen. This is so that you can paste the address into alternative word processing programs, label writing programs etc.

    20) Added OLE (Object Link And Embedding) to the Main screen. With this you can now drag a selection of appliances from SimplyPats into another OLE enabled program such as Microsoft Word (tm) or Microsoft Excel (tm). The App Id, Description, Test Date, Retest Period, Fail Reason and Notes can be copied.

    Bugs

    1) On the very first running of SimplyPats if the Find Appliance fucntion is used, it fails to find appliance Id's correctly. Clicking on any column heading e.g. Appliance Id to apply a sort to the appliances fixes this issue. However code has now been added to add a default sort on the very first time the program is used.

    2) On starting SimplyPats you were prompted if you wanted to check to see if there is an upgrade available. If you had no internet connection or your firewall was blocking such requests then an error was generated. This bug has been fixed and after an unsuccessful attempt to check for an upgrade the timer is set not to check for an upgrade for another month.

    3) If you selected all but one record in a file and tried to delete them, simplypats crashed. This bug was caused by the addition of the photos in version 6 and has now been fixed.

    4) The Folder Cover report was displaying a caption called Account Number. This displayed the notes from the Customer notes field. This caption and field have been removed from the Folder Cover as they were a special request from a SimplYPats user.

    5) An error trap has been put in to detect if your PC display settings is set to 16bit. SimplyPats need to be run in High Colour 32bit.

    6) On a PC with no version of Microsoft Office installed, the System Information screen was not showing that no office was installed.

    7) On the Import and Update screen when printing the reports, the sort order incorrect, sorting by appliance id actually sorted by retest date, and vice versa

    8) On printing an invoice, if in Print Settings you had ticked the box to print Contact name at start of address, and then not entered a contact name, you would get a blank line at the start of the customer address, this has now been checked for and removed.

    9) Ammended the Standard Certificate layout so that overwriting of the order number and the certificate extra text doesn't occur when you have all options set to show the customers full address including their contact name and email etc.

    10) On Printing an Invoice, if you had selected to show the order No in the customer address, this was appearing at the end of the Customer Address on the Invoice, however there is a separate box on the Invoice for order no. The Order No is now not automatically appended to the customer address when printing an invoice.

    11) On Selecting the Kewtech KT74/KT75 from the System Settings screen, the com port selection control was not always shown. This could be fixed by selecting another PAT tester first e.g. a Fluke, then selecting the Kewtech. The com port selector would then be shown. However this problem has now been fixed.

    12) On the Passes, Fails and Passes and Fails reports, if you had used every line of your address and set to show email address, web address etc, the address block was printed very close to the Touch leakage header of those reports. A slightly bigger gap has been introduced.

    13) In very rare circumstances, if the third character of an appliance id is a D or E preceeded by two numbers, and a new manual entry appliance is created then SimplyPats crashes with an error 6 "over flow". This is caused by the routine that tries to calculate the next appliance id on the manual entry screen. It appears appliance id's with letters and numbers are occasionally, very oddly, understood as numeric (for the technical, it sees them as hexadecimal). This problem is now fixed.

    14) When creating a file of only manually entered pat tests, if you selected the Summary Of File screen prior to the file being saved, SimplyPats would crash. This is now fixed.

Version: 6.0.0
  • Additions

  • 1) Rewritten SimplyPats installation program to deal with new Windows 7 operating system.

  • 2) Rewritten all the SimplyPats automatic Emailing functions so that they will work with Windows 7.

  • 3) Added a New screen where you can assign a photograph of your appliance. You can also add notes explaining what the photograph shows.

  • 4) Added a new report showing any photographs assigned to appliances in your SimplyPats data file.

  • 5) Added new fields to store Class, Fuse Rating and Appliance Serial Number.

  • 6) Added Class, Fuse Rating and Appliance Serial Number to the Manual Entry screen.

  • 7) Added new Fields to store RCD and Microwave Test Results.

  • 8) Added new option on Right Hand mouse button (as well as on the records menu) to bring up Enter RCD and/or Microwaves screen.

  • 9) Added New Report to Print Microwave Test Results.

  • 10) Added New Report to Print RCD Test Results.

  • 11) Re done the Current Appliance and Single Appliance per page reports to include Fuse Rating, Class, Appliance Serial No, Microwave and RCD information. The layout of the report has been tidied up to make it look more professional and a line added where a signature can be added.

  • 12) Added a new feature to allow the automatic printing or creation of PDF's for a sequence of reports. You can select which reports you want, to which printer you want the report to be printed and the number of copies of each and whether a PDF is to be printed. This sequence is stored and can then be executed with a single click.

  • 13) Added a new comprehensive Detailed Passed and Fails report.

  • 14) Add a new Folder Cover printed report that gives you a folder cover to present as the front page of your bound reports.

  • 15) Added a New Summary of Repairs screen which lists all the appliances and shows which Repairs and Charge Codes have been applied to each appliance.

  • 16) Changed the List Sites screen to allow you to select multiple sites and save them in one go, rather than having to select each in turn.

  • 17) Auto create disaster recovery file. This feature is designed to backup your file in case your computer crashes, you electricity fails, or you have made serious changes to your data and have accidentally saved the changes. Using this feature you can recover your original data whilst only loosing a maximum of 15 minutes work.

  • 18) Added a New Screen which allows you to Reprint an old SimplyPats Invoice from the file Saved under the Invoicing Screen.

  • 19) Added a check when SimplyPats starts to see if there is an update available from our web site.

  • 20) Renewed the printed Invoice so that it contains the Invoicee address as well as the testing address and also the start and end dates of testing that the invoice covers.

  • 21) Added a new screen "Maintain Location Abbreviations" which allows you to enter abbreviations for locations in your PAT tester. e.g. MR or 101 which will then be converted automatically into "Main Office reception" or whatever full location description you want.

  • 22) Added the ability to edit the Quantity column in the Invoice screen, allowing you to overide the automatically calculated number of tests or repairs before calculatin gthe invoice.

  • 23) New system for licencing SimplyPats Version 6 allows you to change your company name without relicencing the software or contacting our support number.

  • 24) Added Invoicee Address and Testing start Date and Testing End Date to the Invoice file saved under the Invoicing Screen.

  • 25) Changed the way charge and repair codes are displayed on the main screen. Instead of the codes being displayed, the full text descriptions are now being shown.

  • 26) Added a new button to the Customer Quick Select screen which will Import the customer details from a selected customer into the data file you already have open.

  • 27) Added a new button on the Invoicee Details screen that copies the Address details from the Customer Details. This is useful to save time if your invoicee has the same or similar address to the customer, saving you the need to copy type the majority of the information.

  • 28) Added the ability to use custom reports on the internal printouts within SimplyPats e.g. the Missing Appliances report.

  • 29) After downloading a PAT tester the Class field within SimplyPats is automatically calculated for Class I and Class II appliances dependant on their being an Earth Continuity test or not.

  • 30) Added option on Import and Update screen to allow printing of ALL appliances or to select just those Found or those Unfound or those that are new.

  • 31) Amended the allowed length of text in the Extra Invoice text field from 80 characters to 100 characters, in the Print Settings screen.

  • 32) Removed the check when importing a file downloaded with one make of PAT tester into a file created by a different PAT Tester. A message is displayed warning you that mixing files from two different PAT Testers may cause problems, but allows you to override this.

  • 33) Re written the Fluke 6500 download procedure to enable more reliable download with computers using USB to Serial converters with the Prolific Chip set. This should enable higher download speeds to be successful when using USB converters supplied by PC stores.

  • 34) Added a new Export button on the print preview screen which allows the automatic creation of an Adobe Acrobat (tm) PDF document of your printed report and creates and attaches it to an email.

  • 35) Added an option in the System Settings screen that turns off the automatic checking of Post Codes in the Customer, Invoicee and Your Address screens. As more customers outside the UK, New Zealand and Australia use SimplyPats this feature should enable them to enter their own format of post code.

  • 36) Amended the Import and Update function so that any 0 retest periods do not over write the retest period in your master file.

  • 37) Amended the "Backup Your Test Data" screen so that SimplyPats remembers the target path where the compressed data (zip file) is backed up to.

  • 38) Changed the "Backup Your Test Data" screen so that SimplyPats uses the your current data path to find the SimplyPats data files and not the default data path (c:\program Files\SimplyPats 5\Data). This will be more useful if you are saving your data to a network drive or server.

  • 39) Added code to the Import and Update screen so that the settings you select to decide which characteristics of the test data that are updated, are remembered when you re start SimplyPats.

  • 40) Added a new option in the System Settings screen to suppress the question between adding each Manual Entry test result asking if you want to clear your entries. With this new tick box ticked, after adding a manual test result the entries won't be cleared after the test is added and neither will you be asked the question.

  • 41) Amended Save Selected tests to enable the Saving out of just the current test result as a new file. Previously 2 or more tests had to be selected before this option was available.

  • 42) Added a tick box in the System Settings Screen so to swap the use of the Fax Number field in your Customer details to Mobile Phone Number. The mobile phone number or fax is now displayed on the Calendar extra information and also sent to Microsoft Outlook if you are using that feature.

  • 43) Added a function to stop users from hiding the right hand pane of results data completely. The right hand pane will now keep a minimum width.

  • 44) Added 9 extra test price codes from U1 to U9 in addition to the P, PV, T, TV, H, HV, E, EV, and O and OV test price codes.

  • 45) Added another option to the System Settings screen for the Megger PAT4 to allow the storing of either; VA Rating, Room Id, Serial Number or Repair code into the Notes field of SimplyPats.

  • 46) Amended the Invoice printing in SimplyPats to now show ABN Reg. as opposed to GST Reg. if your PC regional settings are set to Australia.

  • 47) Added a new sort order to the printing of reports. "Appliance Id (Strict)" sort order will order the appliances numerically on the Passes and Fails reports and override the default listing or site and location sort order.

  • 48) Added an error trap to the Your Settings screen where you add a company logo or signature image. If an Invalid image is selected e.g. a JPG saved in CMYK a message will explain rather than just getting an error code.

  • 49) Amend the installation routine of SimplyPats. If you re insert your SimplyPats CD on a PC that already has SimplyPats installed you will be told to uninstall the current copy of SimplyPats first. This will allow you to browse the SimplyPats installation CD for the Drivers for the USB to Serial converter that we commonly supply.

  • 50) Removed the pop up message when SimplyPats starts if you have set a fixed Com Port. A static message appears in System Settings, PAT Settings to remind you that a fixed com port is set.

  • 51) Amended the maximum allowable retest period to 72 Months. This will be available by default on new installations of SimplyPats 5.3.0 or above, however to use 72 months on existing installations of SimplyPats you will need to edit the SimplyPats Retest Periods.ini file. Please contact us if you have problems.

  • 52) Added an optional line of customisable text to appear on the following reports: Passes, Fails, Passes and Fails, Appliance Register, Appliance Register By Group, Current Appliance, One Appliance per Page, Retest grouped By Date and Simplified Passes and Fails. This text can be set in the Print setup screen and maybe used to display for example your ISO9002 Registration, or the PAT tester Serial Numbers used in the testing.

  • 53) Added a new drop down on the Manual Entry screen to select the Engineer or User that carried out the test, this saves you having to bulk change the users after entering your manual test results.

  • 54) Changed the sort order on the print out of the Maintain Abbreviations screen. There are 2 columns, the print out now prints down then across, as opposed to across then down.

  • 55) Added a setting to prevent the saving of data from SimplyPats, this may be useful where you want to have a copy of SimplyPats running on a PC where you don’t want to let people edit and then save the data. Contact support for details on this setting.

  • 56) Added the facility to upload tests back to the Transmille 6080 Plus Pat Tester. Please contact support for an explanation of what data can be uploaded.

  • 57) Added Test Date and Retest Date to the import and update screen.

  • 58) Added Print Sort order drop down on Import and Update screen.

  • 59) Amended Bulk Change Screen and Bulk Change of a Selection of appliances screen to allow Bulk change of Class and Fuse Rating.

  • 60) When downloading the Megger PAT4 the fuse rating from the PAT tester is now download and stored in the fuse field in SimplyPats.

  • 61) On the import and update screen added checks to update Fuse, class and Appliance Serial Number as well as RCD and Microwave tests within the checks for Test Data that is being updated.

  • 62) As Support for SimplyPats is now provided free of charge, the need for Support Number has been removed from the Licencing screen.

  • 63) Amended the Replace abbreviations routine to only warn of too long replacements at the end, rather than on each replacement that makes the appliance description greater than 50 characters.

  • 64) Rewritten Print Sequence, Backup Data, System Settings and Diagnostic Download screens to cater for Windows 7 operating System.

  • 65) Amended PAT4 Download routine to cater for an out of range Earth Leakage result where the PAT4 Sends a > symbol to signify a earth leakage of greater than 15mA but sets the pass fail flag on the test to a pass.

  • 66) Changed format on the Repairs area of the Main screen so that where a repair doesn’t have an amount with it, no value is shown in the amount column as opposed to a zero value.

  • 67) Added an optional setting in the .ini file of SimplyPats which will allow the use of some punctuation (full stop, apostrophe and dash) in your abbreviations so you can have an abbreviation HH-FF for example, without SimplyPats thinking it is 2 separate abbreviations HH and FF.

  • 68) Added 3 Tick Boxes to the Print Setup screen to allow you to display (or hide) the Customers Contact Name, Order Number and/ or Email address on the Printed reports from SimplyPats.

  • 69) Re visited all the Printed Reports and tidied all their layouts.
  • Bugs

  • 1) Amended reading of PATLink .opt files to ensure .opt files created by version 1 of PATLink when downloading the New Zealand / Australian variant of the AlphaPat are read correctly.

  • 2) Flash test results were not correctly displayed on the Pass and Fails Report, they were all set to being skipped. This bug had been introduced when changes were made to Australian and New Zealand firmware versions of some PAT Testers. Flash test results are now shown correctly on this report.

  • 3) Fixed a bug that prevented a customised "Simplified Passes and Fails" Report from being loaded.

  • 4) On the extra information displayed when clicking on a customer in the retest calendar, the Surname and Forename of the customer were swapped, giving "Mr Smith John" rather than "Mr John Smith" this has now been fixed.

  • 5) When using the Import and Update feature, if Importing into a file that contains only one test an error was caused. Whilst it is unlikely that you would ever be maintaining a data file with just one test in, this bug has now been fixed.

  • 6) When replacing abbreviations, if an appliance description contained a number e.g. "36.5" and an abbreviation was replaced on that description, the full stop was being removed from the number e.g. "36 5" and replaced with a space. This would also happen if commas or other punctuation was used. This has now been fixed.

  • 7) On the Single Appliance Per Page report, if no Retest Periods were entered in the data then the Retest Date displayed was incorrect. This has now been fixed so the Retest Date displays the same date as the test date.

  • 8) On downloading the Fluke 6500 if you had set to store the contents of the notes field on the PAT into the Retest Period in SimplyPats and the notes had contained very large numbers (for a retest period e.g. greater than 99 months) an error 6 was generated. Any very large retest periods are now ignored.

  • 9) When using the find duplicates function, if there were more than 20 occurrences of the same Appliance Id then SimplyPats reports an error and stopped. It was only envisaged that there would be 2 or 3 occurrences of the same Appliance Id in a file at most. We have now increased the maximum permissible occurrences of the same Appliance Id to 100 in a data file. This error is only likely to happen if you are not using unique appliance id's or giving your appliances all the same id.

  • 10) On the import and update feature, if you imported a file that contained information in the notes field, the existing notes field was only being overwritten if it was blank. Now, if you have the tick box set to import the notes field, the existing notes are always overwritten.

  • 11) The import and update feature was only changing 1 item of the extra data out of the Notes, User, Fail Reason, Retest Period, PAT Serial, this has now been fixed so if any or all of these extra items are changed then they are imported.

  • 12) On the List Sites and List Locations screens, if any sites or locations were listed that were all numeric e.g. a Site Called 1234 then the site was displayed as 1,234.00 that is in full number format. This has now been fixed and all numeric sites or locations are left unformatted.

  • 13) When saving a Site from the list sites screen, if the Site name contained punctuation the SimplyPats couldn't save the file without you editing the filename. Now any illegal filename characters are stripped out of the filename.

  • 14) SimplyPats was incorrectly determining which Version of Microsoft Office you were using, particularly with office 2007. This has now been fixed.

  • 15) If you had set a VAT rate and details in the Your Settings screen created an invoice and then cleared the VAT details by selecting Tax type NONE and then created the invoice again, a run time error was produced. This fault clears itself if you restart SimplyPats after selecting tax type NONE, however in Version 6 the problem has been fixed.

  • 16) After bulk replacing site or location on a selection of tests the List Sites or List Locations screens were not showing the new Site or Location. This has now been fixed.

  • 17) When bulk replacing Appliance Description, Site or Location on a selection of tests if the new entry was entered in lower case then SimplyPats would display the new details in lower case. This would remain until the file was saved. Now entries are converted to upper case.

  • 18) When writing a Microsoft Word document (tm) from the retest calendar screen on some users PC's a run time error 5 was presented, although the document was correctly created, this was as SimplyPats tried to bring the document to the front so you could edit it. This code has been rewritten to avoid this error.